CommonTA SetupDIFs(Country)Select country (TA201 and TA301)
(Sw Type)Select CO switch type
(LDN)Enter LDN (Non North-American)
(SPID)North America only
(ID)North America only
(Lcl Chk)TA101 only
Reset
I/F
Sub addr
LB
(Inband)TA 101 only
(LLC)
TA CnfgsLoadLoad a stored TA configuration
SaveSave current TA configuration
Del entryDelete a stored entry
Clear allClear TA storage memory
Conn TimeLCD DisplayActivate LCD display
Dspl TimeDisplay connect time
Clr TimeClear timer
Dspl Num Show dialed number
Auto AnsSet TA to auto answer
AutoReConSet TA to redial when connection fails
RedialSet number of redial attempts
Dial TOSet dialing time-out
RCProtpcolSet TA remote control protocol
Dig I/F Def I/FDefine Digital Interface Module
DTR/CONSet state of DTR/CON
Spd DialSave CrntSave current configuration and numbers
View dirView speed dial directory
Edit dirEdit a speed dial entry
Add entryAdd a speed dial entry
Del entryDelete a speed dial entry
Clear allClead directory (cannot be recovered)
System LBSys LB Toggle loop-back state
LpBkBrSet loop-back bit rate
ANC DataFmt/L2Enc FmtSet L2 ancillary data format (outbound)
Dec FmtSet L2 ancillary data format (inbound)
Fmt/L3Enc FmtSet L3 ancillary data format (outbound)
Dec FmtSet L3 ancillary data format (inbound)
Asy AdataMUX RateSet data rate
DSP RateSet DSP rate (must be higher than data rate)
Mux ModeSet Mux mode
User ProfileLoadLoad user defaults
SaveSave current configuration as user default
ResetClear user defaults
RPRmt Ctl Set IDSet rear panel RS485 RC port ID
InterfaceSelect RS232 or RS485 remote control
Port baudSelect rear panel RC port baud
Protocol Select rear panel RC protocol usage
EchoSelect response echo
485 modeSelect RS485 mode
FPRmt CtlFP baudSelect front panel RC port baud
FP protoSelect front panel RC protocol usage
EchoSelect response echo
Time CodeDsply srcSet TC readout source
Dsply spdPrint TC speed
Dsply lastDisplay last TC received
On/OffToggle TC readout
LoginUserLog in as user, security level 4
Sup UserLog in as super user, security level 7
FactoryLog in as factory support, security level 9
LogoffReturn to security level 1
Lvl LEDsModeSet level meter mode
MessageScroll message on LED display
IntensitySet LED intensity
PLLPtr evntPrint events input state
Stop timerStop internal timer
ProgramSet event to action logic
Set timerStart internal timer
StatusDIF StateDisplay DIF state
DIF EnablDisplay DIF enable status
LS ClearClear action word latched value
LS ReadRead action word latched value
RS ReadPrimt real-time action word
Virt ActDefine a virtual action
Hot KeyDefine a hot key function
GeneralVersionPrint software module version number
Set DfltsReset to factory defaults
G.722/H.221Set compatibility with PKI telephones
Other RS232UsageSet/activate other RS232 port usage
Baud RateSet RS232 port baud rate
CR timoutSet RS232 response time out
CR cmdSend command from RC port to far-end RS232 port
EOM cmdTerminated with this srting
BuzzerPB clickToggle state of keypress beeper
BuzzerToggle buzzer
FanToggle fan state
ContrastAdjust LCD display contrast





EncoderQstatusDisplay encoder settings
Bit rateSet encoder bit rate
AlgorithmSet encoder algorithm
Algo modeSet algorithm mode
Line fmtSelect line format and lines to use
Smpl rateSelect encoder sample rate
MoreGeneralTimingSet timing source for encoder
ACEEnable/disable advanced concealment of errors
Cal ADRecalibrate A/D converter
Sine DetToggle state of sine detector
Audio InCopy/SwapDuplicate or swap audio channels
Mono mixMix stereo source to mono
ISO HdrCopyrightToggle copyright bit in MPEG header
EmphasisToggle emphasis bit in MPEG header
OriginalToggle original bit in MPEG header
ProtectToggle protect bit in MPEG header
PrivateToggle private bit in MPEG header
ContactsSet SwitchSet a simulated switch
X-Inputs X-StatusDisplay status of various extended inputs
EnableEnable various extended inputs
InvertInvers various extended inputs
PsychoSet ParmSet psychoacoustic parameter
ResetLoad all default parameters
Tbl NumGet number of default table
Load TblLoad table from flash memory
Store TblStore (modified) table in flash memory
Assign TblAssign a table to use





DecoderQstatusDisplay decoder settings
IndepSets encoder/decoder interaction
Line fmtSelects decoder line format and lines
Bit rateSelect decoder bit rate
AESTimingSrcSelect AES/EBU timing
Output SRSelect AES/EBU sample rate
SyncSelect AES/EBU sync source
MoreAudio outMuteMute decoder
Copy/SwapDuplicate or swap audio channels
Algo ModeSet decoding mode
ACEEnable/disable advanced concealment of errors
Cal DARecalibrate D/A converter
AlgorithmSelect decoding algorithm
Stat bitsDisplay real-time status of header bits





MaintQuiet DetTime leftDisplay quiet detector time left
Set lvlSet quiet detector level
Set timeSet quied detector duration
Read lvlRead quiet detector level
Peak DetPeak levDisplay peak audio level
BER DetDsply cntDisplay BER test count
Reset cntReset BER counter
Set threshSet BER event threshold
Set PeakSet BER counter maximum
Up CntSet up count level
Down CntSet down count level
OOF DetDsply cntDisplay OOF test count
Reset cntReset OOF counter
Set threshSet OOF event threshold
Set PeakSet OOF counter maximum
Up CntSet up count level
Down CntSet down count level
Hrdw TestsEnDis TstEnable hardware testing
Hrdwr TstPerform hardware testing
SecurityUser pwdChanger user password
SUser pwdChange super user password
Lock OutSet access to Prima
StatusVer NumDisplay version number of software module
Soft DldBoot ROMBoot from ROM
FE BROMBoot the far-end Prima from ROM
RPRC SrcSet rear panel RC source
RmtBt EnbEnable remote boot
BBM SyncSynchronize RAM and BBM
DebugWtch PrtSet watch port